technology


Function of the Explosion Generator


 

1.    Filling of Dosing Tanks

A programmable logic control opens the solenoid valves of the gas supply and two dosing tanks are filled with oxygen and a combustible gas (methane or similar) until the pre-set pressure is reached. The solenoid valves are closed keeping the two gases separated and therefore non-explosive.

Filling of Dosing Tanks
Filling of Dosing Tanks

2.    Transfer and Mixing

Transfer valves are opened and the two gases are mixed in the high-pressure explosion chambers. After closing the transfer valves a piston closes the discharge tube gastight.

Transfer and Mixing
Transfer and Mixing
 

3.    Explosion and Injection of Pressure Wave into the Plant

The explosive mixture of gas is ignited and once the pressure in the explosion chamber reaches a pre-set value the piston moves backward and the discharge port is opened. A pressure wave is transmitted into the plant through the connection pipe, initially at up to 350 bars. After the pressure wave was ejected, the piston moves to its original position and closes the discharge port. The Explosion Generator is ready for the next explosion.


 
Explosion and Injection of Pressure Wave into the Plant
Explosion and Injection of Pressure Waveinto the Plant

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Intellectual Property / Patents

The Services and goods described in these pages are protected by international trade marks and patents, among others by Chinese Utility Patent No. ZL02811666.6

Partners

China
HongKong
Switzerland
Sweden
Germany
Netherlands
UK

Address

Explosion Power Hong Kong Limited
Unit 13, 6/F., Kwong Sang Hong Centre
151-153 Hoi Bun Road
Kwun Tong, Kowloon
HONG KONG
TEL: +852 2563 7787
Copyright © Explosion Power Hong Kong Limited